Product Series Brief Summary — 97 SKU Summary

Pulse Valve Full Series

Five core product lines covering every gas-tightness class and port size we build — from encapsulated Ex mb valves to ultra-large DN400 tank-mounted units. Use this page as the master spec sheet when matching a model number to your baghouse.

Xiechang® pulse valve full series — main product photo

Collective Operating Conditions

One envelope, four standard-pressure series.

Environment Temp−34°C to 200°C
Working Pressure0.05–0.1 MPa, 0.2–0.6 MPa (incl. low-pressure series)
Size Range3/4″ (DN20) to 16″ (DN400)
Ex-proof RatingGas IIC and Dust explosion-proof
Applied MaterialsAluminum alloy; stainless steel (customized)

Full Spec Sheet

97 SKUs, by series.

1. Encapsulated Pulse Valves

Ex mb Series

0.2–0.6 MPa · −20–80°C / −19–200°C (standard diaphragm) · −34–100°C / −19–200°C (Continental® premium diaphragm)

TypeModel No.Size (Inch)Spec (Metric)Conditions / Remarks
Right-AngleDCF-F-Z-203/4″DN20Ex mb IIC T6 Gb
Right-AngleDCF-F-Z-251″DN25Ex mb IIC T6 Gb
Right-AngleDCF-F-Z-40S1.5″DN40Ex mb IIC T6 Gb
Right-AngleDCF-F-Z-50S2″DN50Ex mb IIC T6 Gb
Right-AngleDCF-F-Z-62S2.5″DN65Ex mb IIC T6 Gb
Right-AngleDCF-F-Z-76S3″DN80Ex mb IIC T6 Gb
Right-AngleDCF-F-Z-102S4″DN100Ex mb IIC T6 Gb
SubmergedDCF-F-Y-251″DN25Ex mb IIC T6 Gb
SubmergedDCF-F-Y-40S1.5″DN40Ex mb IIC T6 Gb
SubmergedDCF-F-Y-50S2″DN50Ex mb IIC T6 Gb
SubmergedDCF-F-Y-62S2.5″DN65Ex mb IIC T6 Gb
SubmergedDCF-F-Y-76S3″DN80Ex mb IIC T6 Gb
SubmergedDCF-F-Y-102S4″DN100Ex mb IIC T6 Gb
Male ThreadDCF-F-ZM-203/4″DN20Ex mb IIC T6 Gb
Male ThreadDCF-F-ZM-251″DN25Ex mb IIC T6 Gb
Male ThreadDCF-F-ZM-40S1.5″DN40Ex mb IIC T6 Gb
StraightDCF-F-T-25S1″DN25Ex mb IIC T6 Gb
StraightDCF-F-T-40S1.5″DN40Ex mb IIC T6 Gb
StraightDCF-F-T-50S2″DN50Ex mb IIC T6 Gb
Right-AngleDCF-F-2L-B3/4″DN20Double Diaphragm
SubmergedDCF-F-YQ-76S3″DN80Low Pressure Type
SpecialDMY-F-II-803″DN80Reinforced Version
Right-AngleDCF-F-Z-25S1″DN25High Frequency Version

2. Flameproof Pulse Valves

Ex db Series

0.2–0.6 MPa · −20–80°C / −19–200°C (standard diaphragm) · −34–100°C / −19–200°C (Continental® premium diaphragm)

TypeModel No.Size (Inch)Spec (Metric)Conditions / Remarks
Right-AngleDCF-F2-Z-203/4″DN20Ex db IIC T6 Gb
Right-AngleDCF-F2-Z-251″DN25Ex db IIC T6 Gb
Right-AngleDCF-F2-Z-40S1.5″DN40Ex db IIC T6 Gb
Right-AngleDCF-F2-Z-50S2″DN50Ex db IIC T6 Gb
Right-AngleDCF-F2-Z-62S2.5″DN65Ex db IIC T6 Gb
Right-AngleDCF-F2-Z-76S3″DN80Ex db IIC T6 Gb
Right-AngleDCF-F2-Z-102S4″DN100Ex db IIC T6 Gb
SubmergedDCF-F2-Y-251″DN25Ex db IIC T6 Gb
SubmergedDCF-F2-Y-40S1.5″DN40Ex db IIC T6 Gb
SubmergedDCF-F2-Y-50S2″DN50Ex db IIC T6 Gb
SubmergedDCF-F2-Y-62S2.5″DN65Ex db IIC T6 Gb
SubmergedDCF-F2-Y-76S3″DN80Ex db IIC T6 Gb
SubmergedDCF-F2-Y-102S4″DN100Ex db IIC T6 Gb
Male ThreadDCF-F2-ZM-203/4″DN20Ex db IIC T6 Gb
Male ThreadDCF-F2-ZM-251″DN25Ex db IIC T6 Gb
Male ThreadDCF-F2-ZM-40S1.5″DN40Ex db IIC T6 Gb
StraightDCF-F2-T-25S1″DN25Ex db IIC T6 Gb
StraightDCF-F2-T-40S1.5″DN40Ex db IIC T6 Gb
StraightDCF-F2-T-50S2″DN50Ex db IIC T6 Gb
Right-AngleDCF-F2-2L-B3/4″DN20High Reliability
SubmergedDCF-F2-YQ-76S3″DN80Hazardous Dust Environments
SpecialDMY-F2-II-803″DN80Custom Explosion-proof
Right-AngleDCF-F2-Z-102S.B3.5″DN90Ex db IIC T6 Gb

3. Pneumatic Pulse Valves

Air-Operated

0.2–0.6 MPa · −20–80°C / −19–200°C (standard diaphragm) · −34–100°C / −19–200°C (Continental® premium diaphragm)

TypeModel No.Size (Inch)Spec (Metric)Conditions / Remarks
SubmergedDCF-Y-25-DXK1″DN25No Electricity Required
SubmergedDCF-Y-40S-DXK1.5″DN40No Electricity Required
SubmergedDCF-Y-50S-DXK2″DN50No Electricity Required
SubmergedDCF-Y-62S-DXK2.5″DN65No Electricity Required
SubmergedDCF-Y-76S-DXK3″DN80No Electricity Required
SubmergedDCF-Y-102S-DXK4″DN100No Electricity Required
Right-AngleDCF-Z-20-DXK3/4″DN20No Electricity Required
Right-AngleDCF-Z-25-DXK1″DN25No Electricity Required
Right-AngleDCF-Z-40S-DXK1.5″DN40No Electricity Required
Right-AngleDCF-Z-50S-DXK2″DN50No Electricity Required
Right-AngleDCF-Z-62S-DXK2.5″DN65No Electricity Required
Right-AngleDCF-Z-76S-DXK3″DN80No Electricity Required
Right-AngleDCF-Z-102S-DXK4″DN100No Electricity Required
Male ThreadDCF-ZM-20-DXK3/4″DN20Pneumatic Trigger
Male ThreadDCF-ZM-25-DXK1″DN25Pneumatic Trigger
Male ThreadDCF-ZM-40S-DXK1.5″DN40Pneumatic Trigger
StraightDCF-T-25S-DXK1″DN25Pneumatic Trigger
StraightDCF-T-40S-DXK1.5″DN40Pneumatic Trigger
StraightDCF-T-50S-DXK2″DN50Pneumatic Trigger
Right-AngleDCF-2L-B-DXK3/4″DN20Pneumatic Control
SubmergedDCF-YQ-76S-DXK3″DN80Pneumatic Control
SpecialDMY-II-80-DXK3″DN80Reinforced Pneumatic
Right-AngleDCF-Z-25S-DXK1″DN25High Frequency Pneumatic

4. Standard Series Pulse Valves

Industrial

0.2–0.6 MPa · −20–80°C / −19–200°C (standard diaphragm) · −34–100°C / −19–200°C (Continental® premium diaphragm)

TypeModel No.Size (Inch)Spec (Metric)Conditions / Remarks
Right-AngleDCF-Z-203/4″DN20Standard Industrial
Right-AngleDCF-Z-251″DN25Standard Industrial
Right-AngleDCF-Z-40S1.5″DN40Standard Industrial
Right-AngleDCF-Z-50S2″DN50Standard Industrial
Right-AngleDCF-Z-62S2.5″DN65Standard Industrial
Right-AngleDCF-Z-76S3″DN80Standard Industrial
Right-AngleDCF-Z-102S4″DN100Standard Industrial
SubmergedDCF-Y-251″DN25Standard Industrial
SubmergedDCF-Y-40S1.5″DN40Standard Industrial
SubmergedDCF-Y-50S2″DN50Standard Industrial
SubmergedDCF-Y-62S2.5″DN65Standard Industrial
SubmergedDCF-Y-76S3″DN80Standard Industrial
SubmergedDCF-Y-102S4″DN100Standard Industrial
Male ThreadDCF-ZM-203/4″DN20Standard Industrial
Male ThreadDCF-ZM-251″DN25Standard Industrial
Male ThreadDCF-ZM-40S1.5″DN40Standard Industrial
StraightDCF-T-25S1″DN25Standard Industrial
StraightDCF-T-40S1.5″DN40Standard Industrial
StraightDCF-T-50S2″DN50Standard Industrial
Right-AngleDCF-2L-B3/4″DN20Classic Model
SubmergedDCF-YQ-76S3″DN80Low Pressure Type
SpecialDMY-II-803″DN80Universal Reinforced
Right-AngleDCF-Z-25S1″DN25Classic Enhanced

5. Large Scale Series

Ultra-Large Ports

0.05–0.1 MPa · −25°C to 100°C continuous, 120°C transient/peak

TypeModel No.Size (Inch)Spec (Metric)Conditions / Remarks
SubmergedDMY-III-200C8″DN200For Ultra-High Flow Tanks
SubmergedDMY-III-250C10″DN250For Ultra-High Flow Tanks
SubmergedDMY-III-300C12″DN300For Ultra-High Flow Tanks
SubmergedDMY-III-350C14″DN350For Ultra-High Flow Tanks
SubmergedDMY-III-400C16″DN400For Ultra-High Flow Tanks

Why Xiechang®

34 years building one component — the pulse valve.

Every model on this page shares the same diaphragm-and-pilot architecture validated since 1992, scaled across five gas-tightness classes and a 3/4″–16″ size range so one manufacturer can spec your whole baghouse line.

Certifications
  • CCC
  • CE
  • IEC Ex
  • IP67
  • ROHS
  • EAC
  • IP65

Independent inspection and Ex-proof certificates cover Zone 1/2 hazardous installations across the Encapsulated and Flameproof series.

Product Videos

Related demonstrations and selection videos.

View All
Related Video0:47

Externally Threaded Right-Angle Pulse Valve Installation Guide & Precautions

Related Video0:28

Male-Thread Right-Angle Pulse Valve Selection Guide | Xiechang ZM Series

Related Video4:43

Xiechang Baghouse Pulse Valves: Dust Collection Solutions Since 1992

Related Video0:37

How to Validate Pulse Jet Valve Performance: Flow, KV & Response Time Analysis | Xiechang

Related Video1:00

Exploring the High-Performance Xiechang Pulse Valve Gallery 🛠️

Related Video2:50

Pulse Valve Not Working? How to Troubleshoot & Repair Your Dust Collector Valve

Certifications

Third-party certified for this product line.

View all certificates →
SGS CE Verification of Compliance (EMC) — DCF Series Pulse Valves🔍 Click to enlarge

Product Certification

Models covered (19)

DCF-Z-25-E · DCF-Z/Y/ZM-20 · DCF-Z/Y/T/ZM-25 · DCF-Z/Y/T/ZM-40S · DCF-Z/Y/T-50S · DCF-Z/Y-62S · DCF-Z/Y-76S · DCF-Z/Y-102S.B · DCF-Z/Y-102S · DCF-Y-115S · DCF-Z/Y/ZM-20-E · DCF-Z/Y/T/ZM-25-E · DCF-Z/Y/T/ZM-40S-E · DCF-Z/Y/T-50S-E · DCF-Z/Y-62S-E · DCF-Z/Y-76S-E · DCF-Z/Y-102S.B-E · DCF-Z/Y-102S-E · DCF-Y-115S-E

SGS CE Verification of Compliance (EMC) — DCF Series Pulse Valves

Certificate No.SHEM250300138601HSC
Issued bySGS-CSTC Standards Technical Services Co., Ltd.
Issued2025-03-25
StandardsEN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019
Need the original PDF?
EAC Declaration of Conformity — Solenoid Pulse Valves (DCF / DMY Series)🔍 Click to enlarge

Product Certification

Models covered (9)

DCF-Y-20/25/40S/50S/62S/76S/102S.B/102S/115S (incl. -JC/C/D/E) · DCF-Z-20/25/40S/50S/62S/76S/102S.B/102S/115S (incl. -JC/C/D/E) · DCF-ZM-20/25/40S (incl. -JC/C/D/E) · DCF-T-25S/40S/50S (incl. -JC/C/D/E) · DMY-II-80 (incl. -JC/C/D/E) · DCF-Y-76S/II-00 (incl. -JC/C/D/E) · DCF-YQ-76S/102S.B/102S (incl. -JC/C/D/E) · DCF-YA-76S/102S.B/102S (incl. -JC/C/D/E) · DCF-Y-20/25/40S/50S/62S/76S/102S.B/102S/115S

EAC Declaration of Conformity — Solenoid Pulse Valves (DCF / DMY Series)

Certificate No.ЕАЭС N RU Д-CN.РА04.В.44367/26
Issued byDeclared by OOO 'Center of Metrology and Standardization' (Moscow) as authorized representative; registered in the Eurasian Economic Union conformity register
Issued2026-05-21
Valid until2031-05-20
StandardsТР ТС 010/2011, ТР ТС 020/2011, ГОСТ 12.2.003-91, ГОСТ 30804.6.2-2013, ГОСТ 30804.6.4-2013, ГОСТ 15150-69, ГОСТ IEC 61000-6-4-2016
Need the original PDF?
CE Statement of Compliance (EMC) — DCF-TZ Solenoid Coil (UL-CCIC)🔍 Click to enlarge

Product Certification

DCF-TZ · DCF-TZ-XQA · DCF-TZ-XQB

CE Statement of Compliance (EMC) — DCF-TZ Solenoid Coil (UL-CCIC)

Certificate No.4790933465-S2
Issued byUL-CCIC Company Limited
Issued2023-08-21
StandardsEN IEC 61000-6-4:2019, EN IEC 61000-6-2:2019
Need the original PDF?
CCEP Environmental Protection Product Certification — DCF Solenoid Pulse Valves🔍 Click to enlarge

Product Certification

DCF series

CCEP Environmental Protection Product Certification — DCF Solenoid Pulse Valves

Certificate No.CCAEPI-EP-2026-039
Issued byCCAEPI — China Association of Environmental Protection Industry (Beijing) Certification Center
Issued2026-01-15
Valid until2029-01-14
StandardsHJ/T 284-2006
Need the original PDF?

Technical Drawings

Installation dimensions for this product.

Knowledge Base

Practical answers for this product.

View All
Troubleshooting

What does moisture in the compressed air do to filters and pulse valves, and how do you prevent it?

Wet air turns the dust cake to paste so it won't shed — blinding bags and keeping DP high; in cold weather trapped moisture can freeze pulse valves. Dry the air with a desiccant dryer, drain condensate routinely, and winterize exposed lines and valves.

moisturewet airdesiccant dryer
Product Q&A

How do you wire the solenoid coil of a Xiechang electromagnetic pulse valve?

For DC24V or AC220V standard coils: unscrew the M3 screw, remove the terminal block, unscrew the gland from the cover, thread the signal wires in, connect the input signal wires to the signal terminals and the earth wire to the ground terminal (AC220V coils must be grounded), then reassemble and tighten the M3 screw.

coil wiringsolenoid wiringDC24V
Product Q&A

What precautions should be taken before, during and after installing an electromagnetic pulse valve?

Before: clean the tank/blow pipe/valve faces, fit an inlet filter + regulator and a bottom drain valve for clean dry air. During: lubricate the immersed-valve O-ring, keep the valve perpendicular to the blow pipe, use PTFE tape, one control circuit per valve. After: no welding on the tank once the valve is fitted, keep pulse width 80–150 ms, insulate in cold climates and bleed the tank before removal.

installation precautionspulse valve installationO-ring lubricant
Product Q&A

What are the main internal components of a Xiechang electromagnetic pulse valve?

From the coil down: solenoid coil and connector, moving iron-core (armature) with its spring, pilot tube, pilot valve seat and pilot spring, the universal (pilot) diaphragm, the valve cover, the large spring, the large main diaphragm, and the valve body — held by M4/M5/M8/M10 fasteners. The coil-driven pilot section controls the large diaphragm that opens and closes the main air flow.

valve structureinternal componentsparts
Product Q&A

What is the Xiechang DXK pilot controller and air-controlled (pneumatic) pulse valve system?

The DXK pilot controller (8, 10 or 12 solenoid positions) drives air-controlled pulse valves through compressed-air lines instead of wiring each valve individually. Controller and air-controlled valves (Z/Y/ZM/T types) must be used together, connected with Ø8 mm semi-rigid nylon tube rated 1 MPa, kept under 1.5 m long.

air-controlled pulse valvepneumatic pulse valveDXK
Product Q&A

What compressed-air pressure should feed the pulse valves, and where should it be measured?

Supply clean dry air at the valve's rated blow pressure and measure it at the manifold, not at a distant plant-air point. Xiechang valves run 0.2–0.6 MPa; general pulse-jet practice is around 6 bar (90 PSI) where valves are rated for it. Never exceed the valve's rated maximum.

pulse pressureblow pressuremanifold gauge